Torque Converter Calculator
Work out what stall speed a torque converter will give behind your engine, its K-factor, how much it multiplies torque at launch, and how much power it turns into heat when it slips. Also converts torque between lb-ft, lb-in, N·m, kgf·m and dyne-cm.
How to Use
- Pick a mode: Stall speed, K-factor, Launch torque, Slip & heat, or Torque units.
- For a new converter, enter its advertised stall speed, the engine torque that rating assumes, and the torque your engine makes near that rpm.
- For launch torque, enter the engine torque, the converter’s stall torque ratio (car converters are about 1.8 to 2.5), the first-gear and axle ratios and the tyre diameter.
- For slip, enter the engine and turbine (transmission input) speeds and the torque ratio at that moment.
- Read the results and the drawing, and follow the working under Show Work.
Worked Example
Moving a stall rating to a smaller engine. A converter is sold as a 3,000 rpm stall, rated behind an engine making 500 lb-ft. Its K-factor is 3,000 ÷ √500 = 134.2. Behind an engine making 400 lb-ft near that speed it stalls at 134.2 × √400 = 2,683 rpm, 317 rpm lower. Hughes Performance tells small-block owners to expect 300–500 rpm less than the advertised figure, which is the same effect.
Launch torque. 400 lb-ft through a converter that multiplies 2.0 times at stall becomes 800 lb-ft at the transmission input, 1,984 lb-ft after a 2.48 first gear and 7,400 lb-ft at the axles with a 3.73 ratio. On 28 in tyres (14 in radius) that pushes on the road with about 6,343 lbf, before gearbox and axle losses.
The common mistake: scaling stall speed in proportion to torque. 25 % less torque does not mean 25 % less stall speed. Because the converter absorbs torque in proportion to rpm squared, 375 lb-ft instead of 500 lb-ft drops a 3,000 rpm stall to 3,000 × √0.75 = 2,598 rpm, not 2,250 rpm.
Show Work
Formulas
How a Converter Behaves
A torque converter is a fluid coupling with a third element. The engine drives the impeller, the fluid it throws drives the turbine on the transmission input shaft, and the stator, held by a one-way clutch, turns the returning fluid round so that it helps the impeller. That is what lets a converter multiply torque when the turbine is turning slower than the engine, something a plain fluid coupling cannot do. Wikipedia’s summary of the literature puts typical stall torque ratios at 1.8:1 to 2.5:1 for cars, and describes three phases: stall (turbine stopped, most multiplication), acceleration (multiplication falling as the turbine speeds up) and coupling (turbine at about 90 % of impeller speed, no multiplication, where a lock-up clutch usually engages).
Hughes Performance defines stall speed as the highest engine rpm reachable in a forward gear without moving the driveshaft, and stresses that every advertised stall figure is nominal: it depends on the torque the engine makes, so the same converter stalls lower behind a smaller engine. TCI adds that flash stall, read off the tachometer as the car leaves at full throttle, is a more accurate measure than foot-brake stall, which depends on the brakes, the axle ratio and the engine’s idle.
The square-root rule follows from the affinity laws for fluid machines (Engineering ToolBox): in a geometrically similar machine the power absorbed rises with the cube of speed, so the torque rises with its square. At stall the speed ratio is fixed at zero, so the engine settles where its torque equals what the impeller absorbs, rpm = K × √torque. Real converters only follow this closely near one operating point, and the engine’s torque changes with rpm, which is why the page asks for the torque near the stall speed.
About This Calculator
This calculator answers the questions people ask when they choose or diagnose a torque converter: what stall speed it will really give behind their engine, what its K-factor is, how much torque reaches the tyres at launch, and how much power the converter turns into heat when it slips. It also keeps the torque unit converter this page used to be, at Torque units, with factors from NIST SP 811.
Converter makers publish a stall range for a stated engine; ask them for the torque their rating assumes. Stall tests heat the transmission fluid quickly, so follow the transmission maker’s procedure. Everything runs in your browser and nothing you enter is sent anywhere.
Related calculators: Horsepower & Torque Calculator, Gear Ratio Calculator, and Bolt Torque Calculator.
Frequently Asked Questions
What is torque converter stall speed?
Hughes Performance defines it as the highest engine rpm reachable in a forward gear without turning the driveshaft. Advertised figures are nominal: Hughes rates its converters behind a big-block street engine and says small blocks typically see 300–500 rpm less. TCI says flash stall, read as the car pulls away at full throttle, is more accurate than foot-brake stall.
How does engine torque change the stall speed?
The torque a fluid coupling absorbs rises with the square of its speed, so stall speed rises with the square root of engine torque. A converter rated 3,000 rpm behind 500 lb-ft stalls at about 3,000 × √(400 ÷ 500) = 2,683 rpm behind 400 lb-ft, 317 rpm lower, which matches the 300–500 rpm Hughes reports for small blocks.
What is a torque converter K-factor?
K = stall rpm ÷ √(engine torque). It describes the converter, not the engine. A converter that stalls at 2,500 rpm with 400 lb-ft has K = 2,500 ÷ 20 = 125; in N·m the same converter is 107.4. Behind 350 lb-ft a K of 150 stalls at 2,806 rpm.
How much does a torque converter multiply torque?
Car converters typically multiply torque 1.8 to 2.5 times at stall, falling to 1:1 as the turbine catches up with the engine. 400 lb-ft through a 2.0 converter, a 2.48 first gear and a 3.73 axle gives 7,400 lb-ft at the axles at launch, twice the 3,700 lb-ft without the converter.
Why does a torque converter make heat?
Its efficiency is torque ratio × speed ratio, and whatever is not passed on heats the fluid. At stall the turbine is not turning, so efficiency is zero: an engine making 350 lb-ft at 2,400 rpm puts 119.3 kW (160 hp) straight into the fluid. At a 0.9 speed ratio with no multiplication the converter is 90 % efficient. Follow the transmission maker’s procedure for any stall test.
How do I use the Torque Converter Calculator?
Simply type your numbers and read the result, which refreshes the instant you change something. There is nothing to submit and nothing to wait for.
Do I need to install or sign up for anything?
Not at all — it runs in the browser with nothing to install and no account. After it loads once, it even works without an internet connection.
Is my information private?
Yes. Everything happens in your browser. Nothing you type is sent to a server or saved anywhere.
Common Use Cases
Choosing a stall converter
A 2,400 rpm converter rated behind 350 lb-ft will stall at about 2,721 rpm behind an engine making 450 lb-ft there.
Comparing converters
Turn each maker’s stall figure and test torque into a K-factor: 2,500 rpm at 400 lb-ft is K = 125 (107.4 in N·m).
Launch torque
400 lb-ft, a 2.0 stall ratio, 2.48 first and 3.73 axle on 28 in tyres push on the road with about 6,343 lbf.
Transmission heat
At a 0.6 speed ratio and 1.4 torque ratio the converter is 84 % efficient and 300 lb-ft at 2,000 rpm puts 13.6 kW into the fluid.
Torque units
100 lb-ft is 135.6 N·m, 1,200 lb-in or 13.83 kgf·m; a 203 N·m spec is 149.7 lb-ft.