Quick reference for thermal-resistance, dissipation, and heatsink selection.
Updated Apr 19, 20262 min read
Core equation
Heat flow
ΔT = P · R_θ (analogous to V = IR)
Junction temp
T_J = T_A + P · (R_θJC + R_θCS + R_θSA)
Derating
Target T_J ≤ 0.8 × T_J,max
Approximate heat transfer coefficients (W/m²·K)
Mechanism
h
Natural convection (air)
5 – 25
Forced convection (air)
10 – 500
Natural convection (water)
50 – 1 000
Forced convection (water)
300 – 12 000
Boiling water
2 500 – 25 000
Radiation (painted matte)
5 – 10 (at 300 K)
Heatsink rules of thumb
Orient fins vertically for natural convection.
Leave 25 mm clearance above/below fins.
Black-anodize fins for +10–15% radiative boost over bare aluminum.
Forced air (small fan) typically halves R_θSA.
Heat pipe inside bigger sinks spreads heat from the die footprint across the full fin area.
TIM: use just enough to wet the surface — excess increases resistance.
Ballpark TO-220 dissipation
Setup
R_θJA
Safe P @ 25 °C ambient
No sink
~60 °C/W
~1.5 W
Small clip sink
~20 °C/W
~4 W
Medium extruded
~8 °C/W
~11 W
Large + fan
~3 °C/W
~30 W
Worked example: picking a heatsink
A TO-220 regulator dissipates 5 W in a 40 °C enclosure. Its maximum junction temperature is 125 °C, and the 80% derating target is 100 °C, so the allowed rise is 60 °C. The total thermal resistance can be at most 60 / 5 = 12 °C/W. Junction-to-case is 3 °C/W and the insulating pad adds 0.5 °C/W, so the heatsink must provide no more than 12 − 3 − 0.5 = 8.5 °C/W. A medium extruded heatsink (about 8 °C/W) just qualifies; a better choice is a smaller one with a fan or one rated near 5 °C/W. With no heatsink at all, 5 W × 60 °C/W = 300 °C would destroy the part.
Convection sanity check: heat leaving a surface is P = h × A × ΔT. A 10 cm by 10 cm plate (0.01 m²) with natural convection h = 10 W/m²K that is 50 °C above ambient sheds 10 × 0.01 × 50 = 5 W. This is why a bare small enclosure cannot dissipate tens of watts without airflow or a finned surface.
Common mistakes
Using ambient temperature outside the enclosure instead of the air temperature inside, which can be 10 to 20 degrees C higher around hot components.
Adding thermal resistances from different datasheets that assume different test conditions. RθJA from a datasheet depends on the test board and is not transferable to your layout.
Forgetting that the heatsink warms its neighbors. A sink at 80 °C is a heat source for nearby capacitors, whose life halves for each 10 °C.
Ignoring the thermal mass for pulsed loads: short pulses can be handled by a part with a large heat capacity even if the average power exceeds the steady-state limit. Use the transient thermal impedance curve in the datasheet.
Was this article helpful?
Cookies & ads
Tools run client-side — your inputs stay in your browser. No ad network is installed, so no ad cookies are set. Choose what this site may store on your device. Privacy · Cookies
Essential StorageTheme, consent state, CSRF tokens. Required for the site to work.
Always on
PersonalizationRecently used tools, custom colors, accessibility preferences. Stored locally on your device.
AdvertisingOnly applies if an ad network is installed. None is today, so no ad cookies are set either way. Details.
AnalyticsAggregate, anonymous page-view counts so we know which tools to improve.
AI IntegrationStores your API key locally for optional AI features. Key never leaves your device.