On a 12 V system, a 20 A load 15 ft from the battery needs 12 AWG copper for a 10 % voltage drop, and 6 AWG for 3 %; a 15 A fuel pump 16 ft away needs 8 AWG at 3 %. Wire size is set by whichever is stricter: the voltage drop over the whole circuit (there and back) or the ampacity, the current the insulation can take without overheating. Then the fuse is chosen to protect the wire: at least 125 % of the load, and no more than the wire is rated for. The figures on this page come from the National Bureau of Standards’ copper wire tables, the ABYC E-11 ampacities and the drop limits published by Blue Sea Systems; see Sources.
Size any circuit with the Automotive Wire Gauge Calculator, which uses the same data.
AWG: why the numbers run backwards
Wire size in North America is given as an AWG (American Wire Gage, formerly the Brown & Sharpe gage) number, and smaller numbers mean thicker wire. NBS Handbook 100 explains that the sizes roughly follow the successive steps of wire drawing, so a larger number means more passes and a thinner wire. The series is geometric: No. 0000 is defined as 0.4600 inch and No. 36 as 0.0050 inch, with 38 sizes between, so each size is 1.1229 times the diameter of the next.
Two shortcuts from the same handbook are worth remembering. Every three gauge numbers the cross-section and the resistance double or halve, and every ten numbers they change by about ten times. And No. 10 copper is about 1 ohm per 1,000 feet, 0.1 inch in diameter and 10,000 circular mils. Sizes thicker than 1 AWG are written 1/0, 2/0, 3/0 and 4/0 (NBS writes them 0, 00, 000 and 0000).
Copper wire data used for sizing
| Gauge (AWG) | Area (mm²) | Diameter (mm) | Resistance (Ω per 1000 ft, 20 °C) | Resistance (Ω per km, 20 °C) | Ampacity outside engine space (A) | Ampacity in engine space (A) |
|---|---|---|---|---|---|---|
| 18 | 0.82 | 1.02 | 6.39 | 20.965 | 20 | 17 |
| 16 | 1.31 | 1.29 | 4.02 | 13.189 | 25 | 21.3 |
| 14 | 2.08 | 1.63 | 2.52 | 8.268 | 35 | 29.8 |
| 12 | 3.31 | 2.05 | 1.59 | 5.217 | 45 | 38.3 |
| 10 | 5.26 | 2.59 | 0.9988 | 3.277 | 60 | 51 |
| 8 | 8.37 | 3.26 | 0.6281 | 2.061 | 80 | 68 |
| 6 | 13.3 | 4.12 | 0.3952 | 1.297 | 120 | 102 |
| 4 | 21.15 | 5.19 | 0.2485 | 0.815 | 160 | 136 |
| 2 | 33.63 | 6.54 | 0.1563 | 0.513 | 210 | 178.5 |
| 1 | 42.41 | 7.35 | 0.1239 | 0.407 | 245 | 208.3 |
| 1/0 | 53.51 | 8.25 | 0.09825 | 0.322 | 285 | 242.3 |
| 2/0 | 67.44 | 9.27 | 0.07793 | 0.256 | 330 | 280.5 |
| 3/0 | 85.03 | 10.40 | 0.06182 | 0.203 | 385 | 327.3 |
| 4/0 | 107.22 | 11.68 | 0.04901 | 0.161 | 445 | 378.3 |
Resistance: solid annealed copper at 20 °C, NBS Handbook 100, Table 5 (stranded conductors are 2 to 5 percent higher). Ampacity: ABYC E-11 for 105 °C insulation, single conductor, as published by West Marine; the engine-space column is 15 % lower. Diameter is the solid-wire diameter from the AWG formula.
Voltage drop: the real reason wire size matters
Every wire has resistance, and current through it loses voltage. On 12 V there is little to spare: a 10 % drop is 1.2 V and a 3 % drop only 0.36 V. A fuel pump that gets 10.8 V instead of 12 V runs slower, lights dim and electronics misbehave.
The 2 matters most: current goes out to the load and back to the battery, so the resistance that counts is the whole loop. Blue Sea Systems’ chart and West Marine’s tables both use this round-trip length. A load 15 ft away has 30 ft of circuit.
The common mistake is to forget the return path. For 20 A to a load 15 ft away at 3 %, using 15 ft instead of 30 ft makes 10 AWG look right, but 10 AWG really drops 20 × 0.9988 × 30 ÷ 1000 = 0.60 V, which is 5.0 %. The correct gauge is 6 AWG: 0.24 V, 2.0 %.
Wire gauge by current and distance: 12 V, 3 % drop
| One-way length (ft) | One-way length (m) | 5 A | 10 A | 15 A | 20 A | 30 A | 40 A | 60 A | 80 A |
|---|---|---|---|---|---|---|---|---|---|
| 5 | 1.5 | 18 | 14 | 12 | 12 | 10 | 8 | 6 | 6 |
| 10 | 3.0 | 14 | 12 | 10 | 8 | 6 | 6 | 4 | 2 |
| 15 | 4.6 | 12 | 10 | 8 | 6 | 6 | 4 | 2 | 1 |
| 20 | 6.1 | 12 | 8 | 6 | 6 | 4 | 2 | 1 | 1/0 |
| 25 | 7.6 | 10 | 8 | 6 | 4 | 2 | 2 | 1/0 | 2/0 |
AWG copper at 20 °C, single wire outside an engine space, length one way (the circuit is twice as long). A gauge in this table is also thick enough for a fuse of 125 % of the load. On 24 V the same drop percentage allows twice the length.
Wire gauge by current and distance: 12 V, 10 % drop
| One-way length (ft) | One-way length (m) | 5 A | 10 A | 15 A | 20 A | 30 A | 40 A | 60 A | 80 A |
|---|---|---|---|---|---|---|---|---|---|
| 5 | 1.5 | 18 | 18 | 18 | 16 | 12 | 10 | 8 | 6 |
| 10 | 3.0 | 18 | 16 | 14 | 14 | 12 | 10 | 8 | 6 |
| 15 | 4.6 | 18 | 14 | 14 | 12 | 10 | 10 | 8 | 6 |
| 20 | 6.1 | 16 | 14 | 12 | 10 | 10 | 8 | 6 | 4 |
| 25 | 7.6 | 16 | 12 | 12 | 10 | 8 | 6 | 6 | 4 |
AWG copper at 20 °C, single wire outside an engine space, length one way (the circuit is twice as long). A gauge in this table is also thick enough for a fuse of 125 % of the load. On 24 V the same drop percentage allows twice the length.
Where published charts differ: these tables are calculated directly from the NBS resistances. Blue Sea Systems’ and West Marine’s printed charts are sometimes one size more conservative. For example, for 10 A over a 20 ft circuit (10 ft each way) at 3 %, the calculation gives 12 AWG (0.32 V) while Blue Sea’s chart shows 10 AWG; for 20 A over a 10 ft circuit at 3 %, Blue Sea shows 12 AWG and West Marine 10 AWG. When in doubt, take the thicker wire.
Ampacity: the heat limit
Ampacity is the current a conductor can carry continuously without its insulation getting too hot. The ABYC values above are for 105 °C insulation; lower-rated insulation carries less. They fall when the wire is in a hot place or bundled with others: West Marine’s guide takes 15 % off in engine spaces (assumed 50 °C instead of 30 °C), 30 % for three bundled conductors, 40 % for four to six and 50 % for seven to 24.
Heat also raises resistance. Copper’s resistance rises by 0.00393 per °C above 20 °C (NBS Handbook 100), so a cable at 60 °C has about 16 % more resistance and drop than the 20 °C figures. For most accessory runs voltage drop forces a thicker wire than ampacity would; for short, heavy runs such as starter or winch cables, ampacity and the fuse set the size.
Car wiring is often SAE J1128 primary cable rather than AWG building or marine wire. West Marine notes that SAE sizes are 6 to 12 percent smaller than AWG sizes and have more resistance, so the same gauge number carries a little less and drops a little more.
Fusing: protecting the wire, not the device
A fuse protects the wire. If a feed shorts to the body, the battery drives a very large current through it; the fuse is the deliberate weak link that opens before the insulation burns. Blue Sea Systems’ rule has two ends:
- Minimum: 125 % of the load current, so normal operation and start-up surges do not blow it. An 80 A load needs at least 100 A.
- Maximum: what the wire is rated for. If the device maker’s fuse is too large to protect the wire, use a bigger wire. Blue Sea’s chart allows up to 150 A on a single 4 AWG wire outside an engine room, and picks 125 A for its 80 A windlass example.
Fit the fuse as close to the battery as practical, so the whole length of the feed is protected. ABYC E-11 requires circuit protection on every ungrounded conductor except those in the engine starting circuit (Blue Sea, citing E-11.10.1.1.1).
Grounds and relays
The ground return is half the circuit. The voltage-drop formula counts its length, so a thin or corroded ground causes the same loss as a thin feed; give it the same gauge and clean, tight connections. For heavy loads switched from the dashboard, use a relay: the dash switch only carries the relay coil current, and the heavy current takes a short, thick, fused path from the battery to the load.
In practice
Find the load’s current (watts ÷ volts if only the power is given), measure the one-way run and double it, pick a drop limit (3 % critical, 10 % non-critical), choose the thinnest gauge that meets it, check the ampacity with any engine-space or bundling derating, then fuse between 125 % of the load and the wire’s rating. The Automotive Wire Gauge Calculator does each step and shows the working; the Voltage Drop Calculator covers other conductors and AC circuits.
Sources
- National Bureau of Standards, Copper Wire Tables, Handbook 100 (1966; first issued as Circular 31, 1912): Table 5 (AWG resistance at 20 °C), Table 17 (stranded conductors), AWG definition and shortcuts, temperature coefficient 0.00393 per °C. nvlpubs.nist.gov
- West Marine, Marine Wire Size and Ampacity (Tom Burden, updated 16 August 2019): ABYC 105 °C ampacities, engine-space and bundling deratings, SAE versus AWG sizes, 3 % and 10 % tables (Ancor wire data).
- Blue Sea Systems, Part 1: Choosing the Correct Wire Size for a DC Circuit (2010) and its DC Wire Selection Chart (2017): 3 % critical / 10 % non-critical voltage drop from ABYC E-11, round-trip length, 80 A windlass example.
- Blue Sea Systems, Part 2: Select a Fuse and Fuse Holder for Your DC Product Installation (2010) and its Fuse Selection Chart (2017): fuse to protect the wire, minimum 125 % of the load, ABYC E-11.10.1.1.1.
- American Boat and Yacht Council (ABYC), standard E-11 (paywalled; the figures above are as quoted by Blue Sea Systems and West Marine).
Frequently asked questions
What gauge wire do I need for a 12-volt accessory?
It depends on the current, the length there and back, and the voltage drop you accept. A 20 A load 15 ft from the battery (30 ft of circuit) needs 12 AWG for a 10 % drop (0.95 V) and 6 AWG for 3 % (0.24 V). A 15 A fuel pump 16 ft away needs 8 AWG at 3 %. Blue Sea Systems, following ABYC E-11, uses 3 % for critical circuits and 10 % for non-critical ones.
Why are smaller AWG numbers thicker wire?
The American Wire Gage numbers run backwards because they follow the steps of wire drawing: each pass through a die makes the wire thinner and the number larger (NBS Handbook 100). Every three gauge numbers the cross-section and the resistance double or halve, and No. 10 copper is about 1 ohm per 1,000 feet. So 10 AWG has about half the resistance of 13 AWG and twice that of 7 AWG.
What decides wire size, heat or voltage drop?
Both, and whichever needs the thicker wire wins. 18 AWG with 105 °C insulation is rated 20 A outside an engine space (ABYC), but carrying 20 A over 30 ft of circuit it would lose 3.8 V on a 12 V system. On longer runs voltage drop sets the size; on very short, high-current runs (a winch cable, a battery cable) ampacity does.
How do I size the fuse for a wire?
The fuse protects the wire. Blue Sea Systems says to pick a fuse that protects the wire according to its rating, and at least 125 % of the load current so it does not blow in normal use. For an 80 A load on 4 AWG that is at least 100 A; Blue Sea’s chart allows up to 150 A for 4 AWG run singly outside an engine room. Never fit a bigger fuse because one keeps blowing.
Does wire in the engine bay need to be thicker?
Yes. West Marine’s ABYC-based guide reduces ampacity by 15 % in engine spaces (taken to be 20 °C hotter) and by 30 % for three bundled conductors, 40 % for four to six and 50 % for seven to 24. Heat also raises copper’s resistance by 0.393 % per °C (NBS), so a wire at 60 °C drops about 16 % more voltage than at 20 °C.