Automotive Wire Gauge Calculator
Find the wire gauge for a 12, 24 or 48 V circuit from the current, the run length and the voltage drop you can accept, check the drop of a wire you already have, or find how far a gauge can reach. Uses ABYC ampacity and the 3 % / 10 % drop limits published by Blue Sea Systems.
How to Use
- Pick a mode: Size finds the gauge, Check drop tests a gauge you already have, Max length finds how far a gauge can reach.
- Enter the load as a current in amps, or as a power in watts, and pick the system voltage.
- Enter the one-way distance from the battery (or fuse block) to the load in feet or metres; the calculator doubles it for the return path.
- Set the voltage-drop limit: 3 % for anything that suffers on low voltage (fuel pumps, electronics), 10 % for non-critical loads such as general lighting.
- Say whether the wire runs in the engine space or in a bundle, and how hot it runs, then read the gauge, the drop and the fuse range; Show Work lists every step.
Worked Example
Blue Sea Systems’ own example. A windlass draws 80 A and sits 25 ft from the battery, so the circuit is 50 ft long. It is a non-critical load, so 10 % (1.2 V on 12 V) is allowed. The wire may have at most 1.2 V ÷ 80 A ÷ 50 ft × 1000 = 0.300 Ω per 1000 ft. 4 AWG has 0.2485 Ω per 1000 ft (6 AWG has 0.3952), so the answer is 4 AWG, losing 0.99 V (8.3 %). Its 160 A rating covers 80 A, and the fuse should be at least 1.25 × 80 = 100 A. Blue Sea’s chart gives the same 4 AWG and picks a 125 A fuse.
A fuel pump at 3 %. 15 A, 16 ft from the battery: 32 ft of circuit and 0.36 V allowed, so at most 0.36 ÷ 15 ÷ 32 × 1000 = 0.750 Ω per 1000 ft. 10 AWG (0.9988) is too thin; 8 AWG (0.6281) loses 0.30 V (2.5 %).
The common mistake: forgetting the return path. For 20 A to a load 15 ft away at 3 %, using only the 15 ft one way gives a limit of 1.2 Ω per 1000 ft, and 10 AWG looks fine. But the current flows through 30 ft of wire, so 10 AWG really drops 20 × 0.9988 × 30 ÷ 1000 = 0.60 V, which is 5.0 %, not 3 %. The right answer is 6 AWG: 0.24 V (2.0 %). Sizing by ampacity alone is the other trap: 18 AWG is rated 20 A, and would lose 3.8 V over that run.
Show Work
Formulas
The Wire Data Used
| Gauge (AWG) | Area (mm²) | Ohms per 1000 ft | Ohms per km | Ampacity (A) |
|---|---|---|---|---|
| 18 | 0.82 | 6.39 | 20.965 | 20 |
| 16 | 1.31 | 4.02 | 13.189 | 25 |
| 14 | 2.08 | 2.52 | 8.268 | 35 |
| 12 | 3.31 | 1.59 | 5.217 | 45 |
| 10 | 5.26 | 0.9988 | 3.277 | 60 |
| 8 | 8.37 | 0.6281 | 2.061 | 80 |
| 6 | 13.3 | 0.3952 | 1.297 | 120 |
| 4 | 21.15 | 0.2485 | 0.815 | 160 |
| 2 | 33.63 | 0.1563 | 0.513 | 210 |
| 1 | 42.41 | 0.1239 | 0.407 | 245 |
| 1/0 | 53.51 | 0.09825 | 0.322 | 285 |
| 2/0 | 67.44 | 0.07793 | 0.256 | 330 |
| 3/0 | 85.03 | 0.06182 | 0.203 | 385 |
| 4/0 | 107.22 | 0.04901 | 0.161 | 445 |
Resistance: solid annealed copper at 20 °C, NBS Handbook 100 Copper Wire Tables, Table 5; stranded conductors are 2 to 5 percent higher. Ampacity: ABYC E-11, 105 °C insulation, outside engine spaces, not bundled, as published in West Marine’s Marine Wire Size and Ampacity guide (Ancor wire data).
Where the Numbers Come From
The American Wire Gage, formerly the Brown & Sharpe gage, is a geometric series: the National Bureau of Standards’ Copper Wire Tables (Handbook 100, first issued as Circular 31 in 1912) defines No. 0000 as 0.4600 inch and No. 36 as 0.0050 inch with 38 sizes between, so each size is 1.1229 times the next. Its handy shortcuts: every three gauge numbers the area and resistance double or halve, and No. 10 copper is about 1 ohm per 1,000 feet, 0.1 inch across and 10,000 circular mils. The resistance values rest on the International Annealed Copper Standard adopted by the International Electrotechnical Commission in 1913, with a temperature coefficient of 0.00393 per °C at 20 °C, which is why a wire at 60 °C has about 16 % more resistance than at 20 °C.
The sizing rules come from the boating world, where the American Boat and Yacht Council’s E-11 standard covers low-voltage DC wiring. Blue Sea Systems distils it into two drop limits: 3 % for critical circuits and 10 % for non-critical ones, with the length always taken as the round trip. West Marine’s guide gives the ABYC ampacity of 105 °C wire and its deratings: 15 % less in engine spaces, which are taken to be 20 °C hotter, and 30 to 50 % less when conductors are bundled. Published charts round differently: for 20 A over a 10 ft circuit (5 ft each way) at 3 %, Blue Sea’s chart and the direct calculation give 12 AWG, while West Marine’s table gives 10 AWG.
Cars use the same physics but different cable: SAE J1128 primary cable sizes are 6 to 12 percent smaller than AWG sizes (West Marine), so the same gauge number has a little more resistance. Where the vehicle maker specifies a wire size or fuse for a circuit, use the maker’s figure.
About This Calculator
This calculator sizes a copper wire run for a 12, 24 or 48 V DC circuit. Size mode finds the thinnest AWG gauge that keeps the voltage drop within your limit and is rated for the current, then steps up a size if a fuse of 125 % of the load would be larger than the wire’s rating. Check drop works out the drop, the voltage at the load and the power lost in a gauge you already have. Max length tells you how far a gauge can carry a load. It allows for running the wire in an engine space, in a bundle, and at a higher temperature.
It is a guide for planning accessory circuits, not a substitute for the vehicle maker’s wiring information. Disconnect the battery before working on wiring, and fuse every new feed close to the battery. Everything runs in your browser and nothing you enter is sent anywhere.
Related calculators: Voltage Drop Calculator, Wire Gauge Calculator, and Battery Life & Runtime Calculator. For the background, read Automotive Wiring: Wire Gauge, Voltage Drop, and Fusing.
Frequently Asked Questions
What gauge wire do I need for 20 amps at 12 volts?
It depends on the length. On ampacity alone, 18 AWG with 105 °C insulation is rated 20 A outside an engine space (ABYC), but that ignores voltage drop. For a load 15 ft from the battery (30 ft of wire there and back), a 10 % drop allows 12 AWG (0.95 V lost) and a 3 % drop needs 6 AWG (0.24 V). At 5 ft and 10 %, 16 AWG is enough.
Should I use a 3 % or a 10 % voltage drop?
Blue Sea Systems, working from the ABYC E-11 standard, uses 3 % for critical circuits (panel feeders, blowers, electronics, navigation lights) and 10 % for non-critical ones (general lighting, windlasses, general appliances). On a vehicle, use 3 % for anything whose performance falls with voltage, such as a fuel pump or electronics. On 12 V, 3 % is 0.36 V and 10 % is 1.2 V.
Why does the calculator double the length?
Current flows out to the load and back to the battery, so the resistance that causes the drop is the whole loop. Blue Sea’s chart and West Marine’s tables both use the round-trip length. A load 25 ft from the battery has 50 ft of circuit; for 80 A at 10 % that needs 4 AWG.
What size fuse goes with the wire?
The fuse protects the wire. Blue Sea Systems says to choose a fuse that protects the wire according to its rating, and at least 125 % of the load current to avoid nuisance blows. For an 80 A load on 4 AWG that is at least 100 A; Blue Sea’s chart allows up to 150 A for 4 AWG run singly outside an engine room, and picks 125 A. Fit it close to the battery.
Is automotive SAE wire the same size as AWG?
No. West Marine’s wire guide (Ancor data) says SAE wire sizes are 6 to 12 percent smaller than AWG sizes, carry proportionally less current and have more resistance. This calculator uses AWG copper (NBS resistance values and ABYC ampacity). With SAE J1128 cable of the same gauge number, check the cable maker’s resistance or allow extra margin.
How do I use the Automotive Wire Gauge Calculator?
Just type your numbers. The answer shows up right away — there is no button to press. Change anything and it updates by itself.
Do I need to install or sign up for anything?
Not at all — it runs in the browser with nothing to install and no account. After it loads once, it even works without an internet connection.
Is my information private?
Yes. Everything happens in your browser. Nothing you type is sent to a server or saved anywhere.
Common Use Cases
LED light bar
A 20 A light bar 15 ft from the battery at a 10 % limit needs 12 AWG: 0.95 V drop (8.0 %) and a 25–45 A fuse range.
Fuel pump
A 15 A pump 16 ft from the battery at 3 % needs 8 AWG, losing 0.30 V (2.5 %).
Audio amplifier
A 60 A amplifier fed from the battery 17 ft away at 3 % needs 2 AWG, with 0.32 V drop and a fuse of at least 75 A.
24 V truck accessory
A 30 A load 25 ft away on 24 V at 3 % needs 6 AWG; the drop is 0.59 V (2.5 %).
Checking existing wire
10 AWG carrying 20 A to a load 20 ft away drops 0.80 V (6.66 %), so it passes a 10 % limit but not 3 %.
Camping fridge in metres
A 5 A, 12 V fridge 5 m from the battery at 3 % needs 12 AWG (3.31 mm²), dropping 0.26 V.